AIDC

AIDC Energy Storage Solutions

A high-safety storage foundation for AI computing centres, rated beyond 10,000 cycles

≥6000

Cycles at room temperature

105

Cell capacity Ah

>94%

Energy efficiency (@25°C, 0.5P)

Scenario Overview

Long-cycle, high-safety storage built on the RockSolid·Craft series for AI computing centre supply, large-model training backup and data centre energy storage.

AI training loads look nothing like a traditional data centre: short spikes, constant swings, and far harsher demands on cycle count and response. The RockSolid·Craft High Safety series uses LFP-Gr and NFPP-HC chemistries with over 10,000 room-temperature cycles, while the semi-solid electrolyte provides an inherent advantage in thermal runaway protection, keeping long-term on-site risk manageable.

Configuration guidance is provided at both rack and container scale, including consistency management when banks are expanded.

Core Capabilities

01

High-safety cell chemistry

LFP-Gr and NFPP-HC with semi-solid electrolyte offer better thermal stability than conventional liquid systems.

02

Rack and container scale options

Capacity ratios and bank layouts are matched to site scale so nothing is over-specified.

03

Batch consistency management

Cells are grouped by batch when banks are expanded, reducing circulating-current risk from mixing old and new packs.

Application Scenarios

Peak shaving and backup for AI centres

Peak shaving and backup for AI centres

Discharging during training power spikes both relieves capacity expansion pressure and serves as emergency backup.

Data centre energy storage

Data centre energy storage

Operating against time-of-use tariffs pushes energy cost into the peak-valley spread.

Customer Value

Higher availability

Long cycle life and high safety together support continuous long-term operation.

Lower lifecycle cost

Doubling cycle count stretches the replacement interval and cuts maintenance spend.

Smoother fire safety review

Complete cell safety test records ease fire approval and site acceptance.

FAQ

Under what conditions is the 10,000-cycle figure measured?

It is measured under standard room-temperature conditions. Real cycle life depends on temperature, depth of discharge and rate; we provide site-specific estimates.

Do you supply integrated cabinets or cells only?

We focus on cells and modules; full cabinet integration can be delivered with partners, with scope agreed per project.

Need a cell configuration matched to your scenario?

Share your system weight, power profile and operating temperature range, and our engineers will return a sizing proposal with preliminary calculations within two working days.